Worcester Bosch · Greenstar Si Compact ErP
EA 227 boiler fault code
Greenstar Si Compact ErP
What EA 227 means
EA 227 indicates that no flame was detected after ignition; documented causes include no or low gas supply, a blocked condensate outlet, or a blocked flue.
Safe check
Contact your gas supplier if the gas supply is interrupted. If safe, look for ice at an accessible condensate outlet and an obvious blockage at the flue outlet from ground level; do not touch the flue. Thaw an accessible frozen condensate pipe from ground level with warm (not boiling) water, then reset once only.
When to contact an engineer
The code remains after one reset, the flue outlet appears blocked, or the condensate outlet cannot be reached safely; arrange a Gas Safe registered engineer.
Safety notice
Source and provenance
- Greenstar Si Compact ErP · 6 720 813 279 · pp. 17–19
installation and maintenance instructions
2014/09 · 6 720 813 279
- Greenstar Si Compact ErP · 6 720 813 278 · p. 70
user instructions
2015/07 · 6 720 813 278
After: Reset the boiler once