Worcester Bosch · Greenstar Si Compact ErP
A1 281 boiler fault code
Greenstar Si Compact ErP
What A1 281 means
Pump stuck or running in air / little or no water in the system.
Gas Safe engineer: If the gauge is not below 1 bar, or A1 returns after following the repressurise step, contact a Gas Safe registered engineer.
Safe check
Check the gauge. If it is below 1 bar, follow the repressurise step: top up to about 1.5 bar using the filling loop as shown by your installer and the user guide, without removing any panel or casing. Otherwise, or if A1 returns, contact a Gas Safe registered engineer.
When to contact an engineer
If the gauge is not below 1 bar, or A1 returns after following the repressurise step, contact a Gas Safe registered engineer.